UAC Parts Catalog
TOOLS & EQUIPMENT / LEAK DETECTION / ELECTRONIC Rev. 11-20-07
UAC PART NO. DESCRIPTION
TO 0135 Maintenance Kit (2 plastic tip covers & 2 Ion Pump Sensors for TO 0790)
TO 0131 Ion Pump Sensor (replacement part for TO 0790)
TO 0132 Aluminum Sensor Housing (replacement part for TO 0790)
TO 0187 Water Vapor Filter (replacement part for TO 0790)

TO 0790
Electronic Leak Detector
  • Detects R12, R134a
  • 18" Flexible Probe
  • Visual Indicator
  • Alarm
  • Touch-key operation (keypads)
  • 10 Different Sensitivity Ranges
  • Low Battery Indicator
  • Automatic Power-off after 15 minutes
TO 1627 Housing (replacement part for TO 0790)
UAC PART NO. DESCRIPTION
TO 0135 Maintenance Kit (2 plastic tip covers & 2 Ion Pump Sensors for TO 0791)
TO 0131 Ion Pump Sensor (replacement part for TO 0791)
TO 0132 Aluminum Sensor Housing (replacement part for TO 0791)
TO 0187 Water Vapor Filter (replacement part for TO 0791)

TO 0791
Electronic Leak Detector
  • Detects R12, R134a
  • 3 position slide switch
  • Audible alarm
  • LED provided (blinking rate is proportional to leak size)
  • Requires 4 AA alkaline batteries
  • 18" flexible probe
UAC PART NO. DESCRIPTION
TO 2809 Tip Filters (x10); (accessory for TO 2800)
UAC PART NO. DESCRIPTION

TO 5075

Halogen Leak Detector, model XL-1 (all halogenated refrigerants)

  • Microprocessor controlled circuit monitors the sensing tip up to 2000 times per second
  • 3VDC, 2 C cell alkaline batteries included
  • 14" stainless steel probe with Teflon liner
  • Sensitivity levels = 1
  • Visual leak indication levels = n/a
  • Two-Year Warranty

TO 5077

Halogen Leak Detector, model XP-1 (all halogenated refrigerants)

  • Microprocessor controlled circuit monitors the sensing tip up to 2000 times per second
  • 3VDC, 2 C cell alkaline batteries included
  • 14" stainless steel probe with Teflon liner
  • Sensitivity levels = 7
  • Visual leak indication levels = 18 (tri-color)
  • Three-Year Warranty

TO 5078

Halogen Leak Detector, model RX-1 (all halogenated refrigerants)

  • Microprocessor controlled circuit monitors the sensing tip up to 2000 times per second
  • 3VDC, 2 C cell alkaline batteries included
  • 14" stainless steel probe with Teflon liner
  • Sensitivity levels = 2
  • Visual leak indication levels = 6 (single color)
  • Two-Year Warranty
UAC PART NO. DESCRIPTION

TO 5079

Halogen Leak Detector, model ZX-1 (all halogenated refrigerants)

  • 16" flexible stainless probe
  • True mechanical pump
  • Heated Pentode Sensor technology:
    • Refrigertant specific detection
    • Elimination of false alarms
    • Unaffected by rapid temperature change
    • Twenty-Five-Year Warranty
UAC PART NO. DESCRIPTION

TO 5080

Leak Detector Kit, model ZX-1KIT
Includes:

  • Storage Case
  • Detector Unit
  • 2 replacement sensors
  • Spare filter elements
  • Remote battery charging base
  • 2 battery chargers (110V, 60 HZ, 12VDC)
  • 2 battery packs (nickel cadmium, nickel-metal hydride)
UAC PART NO. DESCRIPTION

TO 5081

"Inspector" 2 In 1 Electronic / UV Leak Detector

  • Ultra Bright UV/Blue LED Light
  • UV Safety Glasses
  • 6 Levels of Sensitivity (15 Levels of Detection)
  • Tri-Colored Visual Leak Level Indicator
  • Mute Function
  • Detects Leaks as Small as 1/10 oz (3gr) Per Year
  • Custom Molded Carrying Case
UAC PART NO. DESCRIPTION

TO 5082

Electronic Leak Detector

  • 3 Levels of Sensitivity (5 Levels of Detection)
  • Visual Leak Level Indicator
  • Detects Leaks as Small as 1/4 oz (7gr) Per Year
  • Custom Molded Carrying Case
UAC PART NO. DESCRIPTION

TO 5086

"Inspector" 2 In 1 Electronic / UV Leak Detector Kit

This kit offers the "Inspector" along with our UV Dye Injection System. Our cartridge type dye injector is fast and easy to use. Just twist the handle to inject the appropriate amount of dye. The TO 5086 Kit is the ultimate solution for all of your A/C leak detection needs.

UAC PART NO. DESCRIPTION

TO 5550

Electronic Leak Detector W/110V Battery Charger dual UV and Electronic Leak Detection
Includes:

  • UV Goggles
  • 110V Battery Charger
  • 5" Probe Extension
  • 2 C-Size 1.2V NI-MH Batteries
  • Case

Specifications:

  • Operating Temp: 32-125 deg F (0 to 52 deg C)
  • Power Supply: 2 C-Size 1.2V NI-MH Battery
  • Battery Life: 8 hrs per cycle (1000 cycles)
  • Warm-Up Time: 25 seconds
  • Probe/Core Length: 15"
  • Dimension: 7" X 7"
  • Weight: 1.10 lbs. (.49 kg)
  • Ultimate Sensitivity: 1/10 oz (3gr) per yeart

Features:

  • Six Sensitivity Levels
  • Automatic Warm Up
  • Reset Function
  • Dual-colored Visual
    LED Leak Size Display
  • Blue UV LED Light
  • Rechargable NI-MH Battery
  • UV enhancing glasses
  • Dye cleaner
  • Service stickers
  • Storage case
  • Low Battery Indicator
  • High Volume Pump
  • 5" Probe Extension
  • Limited LIFETIME Warranty
  • Detects all Refrigerants (CFC's, HCFC's, HFC's)
  • Meets and Exceeds SAE J1627
  • Made In USA
UAC PART NO. DESCRIPTION

TO 5090

The Yokogawa "Top Gun" Electronic Leak Detector

  • Comfortable pistol grip design with a 16" flexible probe
  • Heated triode, dispersive electron sensor technology with low power drain
  • Sensitivity for all refrigerants
  • Rechargeable Ni-Cad battery
UAC PART NO. DESCRIPTION

TO 5750
Automatic Leak Detector, model 5750A
  • Detects R12, R134a
  • Super Scanner Pump-style
UAC PART NO. DESCRIPTION

TO 6000
Halogen HFC/ CFC / HCFC Leak Detector, model H10A
  • Detects R12, R134a
  • A/C Pump-style
  • 115 Volts AC (230 and 240-volts also available)
  • 48" Probe cord
TO 0555 Maintenance Kit (accessory for TO 6000)
UAC PART NO. DESCRIPTION

TO 6001
Yokogawa Electronic Leak Detector
  • For use in USA
  • Detects R12, R134a
  • Pro Model
  • Manually adjust to zero balance control or automatically auto zero to block out background refrigerant levels
  • Uses positive ion emission heated diode
  • Rechargable internal battery (AC or 12V DC powered)
  • Alarm and visual warning light

TO 6002
Yokogawa Electronic Leak Detector
  • For use in U.K.
  • Detects R12, R134a
  • Pro Model
  • Manually adjust to zero balance control or automatically auto zero to block out background refrigerant levels
  • Uses positive ion emission heated diode
  • Rechargable internal battery (240V AC or 12V DC powered)
  • Alarm and visual warning light

TO 6003
Yokogawa Electronic Leak Detector
  • For use in Europe
  • Detects R12, R134a
  • Pro Model
  • Manually adjust to zero balance control or automatically auto zero to block out background refrigerant levels
  • Uses positive ion emission heated diode
  • Rechargable internal battery (220/230V AC or 12V DC powered)
  • Alarm and visual warning light
TO 6007 14" Bendable Probe Extension
TO 6008 Clear Probe Tip for TO 6001, TO 6002, and TO 6003
TO 6009 Rubber Probe Tip for TO 6001, TO 6002, and TO 6003
TO 6010 Replacement sensor for TO 6001, TO 6002, and TO 6003
TO 6011 Leak Reference Bottle
TO 6012 Tune up kit
Includes:
  • 1 - Replacement Sensor (TO 6010)
  • 1 - Leak Reference Bottle (TO 6011)
  • 3 - Rubber Probe Tips (TO 6009)
  • 3 - Flow Balls
  • 100 - Filters
UAC PART NO. DESCRIPTION

TO 6004
Yokogawa Electronic Leak Detector
  • For use in USA
  • Detects R12, R134a
  • First Model
  • Switch Position (PER YEAR):
    • SMALL .5oz.(R134A), .1oz.(R12)
    • MEDIUM 1oz(R134A), .5oz.(R12)
    • LARGE 5oz(R134A), 3oz.(R12)

TO 6005
Yokogawa Electronic Leak Detector
  • For use in EUROPE
  • Detects R12, R134a
  • First Model
  • Switch Position (PER YEAR):
    • SMALL .5oz.(R134A), .1oz.(R12)
    • MEDIUM 1oz(R134A), .5oz.(R12)
    • LARGE 5oz(R134A), 3oz.(R12)

TO 6006
Yokogawa Electronic Leak Detector
  • For use in UK
  • Detects R12, R134a
  • First Model
  • Switch Position (PER YEAR):
    • SMALL .5oz.(R134A), .1oz.(R12)
    • MEDIUM 1oz(R134A), .5oz.(R12)
    • LARGE 5oz(R134A), 3oz.(R12)
TO 6007 14" Bendable Probe Extension
TO 6008 Clear Probe Tip for TO 6004, TO 6005, and TO 6006
TO 6009 Rubber Probe Tip for TO 6004, TO 6005, and TO 6006
TO 6010 Replacement sensor for TO 6004, TO 6005, and TO 6006
TO 6011 Leak Reference Bottle
TO 6012 Tune up kit
Includes:
  • 1 - Replacement Sensor (TO 6010)
  • 1 - Leak Reference Bottle (TO 6011)
  • 3 - Rubber Probe Tips (TO 6009)
  • 3 - Flow Balls
  • 100 - Filters

TO 6015
H10PA Designed for use with Automotive AC Leaks
  • Powered from an external12VDC source
  • Simply clamp the power cable to car battery
  • Unique heated diode sensor w/ sensitivity ratings exceeding SAE J1627
Universal Air Conditioner // 1441 Heritage Parkway, PO Box 299 // Mansfield, TX 76063
817-740-3900 // fax 817-740-3997