HOME

UAC Parts Catalog

INFORMATION SELECT LIST:
ACCESSING THE DIAGNOSTIC MODE ON ATC SYSTEMS
Model Instructions
Caterpillar/AGCO Challenger With the system On, press the "OUTSIDE AIR TEMPERATURE" button three times to enter the error code mode.

Press and hold the "OUTSIDE AIR TEMPERATURE" button for an additional five seconds to enter the advanced diagnostics real time display.

CNH Windrower Press the "ON" button three times to enter the error code mode.

Press and hold the "ON" button for an additional five seconds to enter the advanced diagnostics real time display.

Freightliner P2 Century Class Available only on the SAE 1708 Data Link
Red Dot With the system On, press the "OUTSIDE AIR TEMPERATURE" button three times to enter the error code mode.
Western Star With system off, press and hold "UP" temperature switch for five seconds to enter error code mode.

Press and hold the "UP" temperature switch for an additional five seconds to enter the advanced diagnostics real time display.

TEMPERATURE SENSOR RESISTANCE CHART
Temperature
Nominal Resistance
°C
°F
3K Ohms
5K Ohms
10K Ohms
66 150 600 1,000 2,000
63 145 700 1,100 2,200
60 140 700 1,200 2,400
57 135 800 1,400 2,700
54 130 900 1,500 3,000
52 125 1,000 1,700 3,300
49 120 1,100 1,900 3,700
46 115 1,300 2,100 4,100
43 110 1,400 2,300 4,600
41 105 1,600 2,600 5,200
38 100 1,800 2,900 5,800
35 95 2,000 3,300 6,500
32 90 2,200 3,700 7,400
29 85 2,500 4,100 8,300
27 80 2,800 4,700 9,400
25 77 3,000 5,000 10,000
24 75 3,100 5,200 10,500
21 70 3,600 5,900 11.900
18 65 4,000 6,700 13,600
16 60 4,600 7,600 15,500
13 55 5,200 8,700 17,700
10 50 5,900 9,900 20,200
7 45 6,800 11,300 23,300
4 40 7,800 13,000 26,700
2 35 9,000 14,900 30,900
-1 30 10,300 17,200 35,700
-4 25 11,900 19,900 41,400
-7 20 13,800 23,000 48,200
-9 15 16,000 26,700 55,900
-12 10 18,700 31,100 65,700
-15 5 21,800 36,300 76,100
-18 0 25,500 42,500 90,300
ERROR CODES
Code Cause
E00 No Faults
E01 Cab Sensor Shorted
E02 Cab Sensor Open
E03 Evaporator Probe Shorted
E04 Evaporator Probe Open
E05 Outlet Sensor Shorted
E06 Outlet Sensor Open
E07 Ambient Sensor Shorted
E08 Ambient Sensor Open
E09 Water Valve Shorted
E10 Water Valve Open

Universal Air Conditioner // 1441 Heritage Parkway, PO Box 299 // Mansfield, TX 76063